Technical information

157
Specifications
General Specifications
AC Input Voltage (Both Logic
and Bridge)
FX-208 through FX-455, 90-264 VAC, 47/63 Hz, Single Phase only, Nominal Voltage = 230 VAC
FX-490 through FX-6120 90-264 VAC, 47/63 Hz, Three Phase, Nominal Voltage = 230 VAC (if single
phase power is used de-rate by 20 percent)
FX-6200 through FX-8400 196-264 VAC, 47/63 Hz, Three Phase only, Nominal Voltage = 230 VAC
Control Modes
Position Control Mode:
Drive Parameters
System Limits
I/O Setup and Configuration
Jog
Home
Indexing
Index Types:
-Incremental-Rotary Clockwise
-Absolute-Rotary Counterclockwise
-Feed to Sensor-Rotary Shortest Path
-Registration
Digital Pulse Follower Mode:
CW/CCW pulses or Pulse/Direction
Analog Mode:
10 bit Analog to Digital Converter
Analog Inputs:
±10.5 VDC Operating Range
±12 VDC Absolute Maximum
Differential Input
Input Impedance: >9 Kohms
Switching Frequency
FX-208 through FX-6120 = 16 kHz
FX-6200, FX-8200 and FX-8300 = 14 kHz
FX-6300 = 13 kHz
FX-8400 = 10 kHz
Velocity Signal Input
±10 VDC Typical (10 bit resolution)
Torque Signal Input
±10 VDC Typical (10 bit resolution)
Pulse Mode Input
TTL voltage compatible, 1.5 µsec. minimum pulse width 210 kHz maximum frequency
Voltage range: 2.4 to 12 Volts
Minimum supply current: 25 mA per single line
Angular Accuracy
±20 arc minutes +21600/SR Where SR = steps/rev
Valid for 200 <SR <4096 with a 15 feet resolver cable
Resolution
12 bit resolver to digital conversion, 4096 positions/revolution
User Units/Rev
Programmable Range: 50 to 25000 steps/revolution
230V FX Series Positioning Drive Reference