Technical information
126
230V FX Series Positioning Drive Reference Manual
one event. If you attempt a Suspend command after the drive has already been suspended and
the Suspend memory has not cleared, the new information will not be retained. You can clear
suspended memory by using the Abort Suspend Function (Input function #33), or a hardware
Stop command (Input function #11).
Suspend Screen Parameters
When you select the Suspend option from the “Define Motion” screen, the Suspend data entry
screen shown in the figure below is displayed.
Figure 88: Suspend Setup Screen
Run Program On Suspend
This feature allows another program to be automatically initiated when a Suspend is accepted.
After the FX drive stops on Suspend, the program you specify in the program number
parameter will be executed without the need for a Program Initiate. This feature is not allowed
during Automatically Suspend Upon Fault.
Program Number
This parameter determines which program is to be initiated when a suspend is accepted and
the “Run Program On Suspend” feature is used. This field appears if Run Program On
Suspend is set to Yes.