Technical information

124
230V FX Series Positioning Drive Reference Manual
The value entered here sets the maximum torque limit that the index will feed to when “Yes
is entered for the Feed To Torque Limit parameter. This value is entered as a percentage of
the maximum torque (200% maximum) available in the drive.
For example, if you are using an FX-208, which has 8 in/lbs of continuous torque, and your
application requires 4 in/lb of torque, you would enter a value of 50 percent.
Feed Sensor Limit Distance
This parameter only appears in Feed To Sensor and Registration Indexes.
This parameter is an incremental distance limit for the feed portion of a Feed To Sensor or
Registration Index (Default of Ø indicates no limit distance.) Hitting this limit completes the
feed portion of the move just as if it had completed normally (by sensors or torque limit
reached) except that the Sensor Limit Hit output is turned on.
Feed Velocity
This parameter only appears in Feed To Sensor and Registration Indexes.
This parameter specifies the maximum velocity the drive will accelerate to during the feed
portion of the index move.
Feed Accel Time
This parameter only appears in Feed To Sensor and Registration Indexes.
This parameter is used to specify the rate at which the drive accelerates during the feed
portion of the index (see "Accel Time" on page 122 for a description).
Feed Decel Time
This parameter only appears in Feed To Sensor and Registration Indexes.
This parameter is used to specify the rate at which the drive decelerates during the feed
portion of the index (see "Decel Time" on page 122 for a description).
Wait For In Position
This parameter appears only if Enable In-Position Window is set to “Yes” in the limits screen.
The Wait For Position parameter is used to Enable/Disable the In Position Window feature
for each index.