Technical information

115
Software Setup and Operation
Feed On/Off/On (home to sensor then off sensor then on sensor)
The “Slow Feed on Velocity should be kept below 50 RPM for the default decel ramp to the
final position.
Figure 82: Feed On/Off/On Home Motion Profile
FEED ON VELOCITY
VELOCITY
TIME
(+)
(-)
ACCEL
INITIATE
HOME SENSOR ON
FEED OFF VELOCITY
HOME
SENSOR OFF
DECEL
SENSOR ON
FEED ON VELOCITY