Technical information

108
230V FX Series Positioning Drive Reference Manual
Figure 73: Jog Setup Screen
Serial, Fast and Slow Velocities
When setting up the Jog parameters, you can set up three velocities: Serial Velocity, Fast
Velocity and Slow Velocity. The acceleration and deceleration times are used for all jog
velocities. When on-line with an FX drive, pressing the space bar initiates and stops the axis
jogging at serial velocity.
All accel times are based from Ø RPM to maximum default motor velocity, not programmed
speed. All decel times are based from maximum default motor velocity to Ø RPM, not
programmed speed. To find the time to reach the velocity you programmed, divide your
velocity by the drives maximum velocity, and multiply the result by the accel time you
entered.
Lock
The Lock feature, when on, will not allow you to Jog until a Home Cycle has been completed.
You must also set Home Lock On in the home screen for Jog Lock to function. To enable Jog
Lock re-cycle logic power to the drive after setting Home and Jog Lock on.