Technical information

105
Software Setup and Operation
10 Sensor Limit Hit
This output activates during a Feed Sensor or Registration index if the Feed Sensor Limit is
exceeded before a sensor signal is received. This output also activates during a home when
the Home Limit Distance is exceeded. This output is deactivates with the Clear Sensor Limit
input. The condition that activates this output is not a fault and the index will continue.
11 End Of Sequence
This output activates after the completion of a motion sequence before the last dwell time (if
any). A motion sequence is completed when a Home, Index, or Program or a combination
thereof, is executed and no further motion commands are given. This output deactivates
automatically with the next motion or when the Clear End Of Sequence input is used.
12 Programmable Outputs
The output lines are assigned this function can be activated or deactivated with the output
programming function.
13 End Of Program
This output is activated after completion of all steps (motion and non-motion) in a Program.
It is automatically deactivated with the next motion or when the Clear End Of Program input
is used.
14 End Of Program Count
This output is activated when the Suspend Program function is active (see “Suspend/Resume”
on page 125 for a complete discussion).
15 In Suspend
This output is activated when the Suspend Program input function is active (see “Suspend/
Resume” on page 125 for a complete discussion on this topic).
16 End of Home (1)
This output activates after the completion of a Home 1 cycle. It is deactivated automatically
with the next motion or when the Clear End Of Home input is used.
19 External Brake Output
This output is active when the bridge is enabled, and inactive when the bridge is disabled.
This output function is used to disengage an external brake when active.