Technical information
104
230V FX Series Positioning Drive Reference Manual
3End Of Index
This output activates after completion of an index. If the Index Count is greater than 1 this
output will activate after each index is completed. It is turned Off automatically with the next
motion or when the Clear End Of Index input is used.
If there is index dwell time, this output will be active this amount of time after the index
movement is complete.
4 End Of Home (0)
This output activates after the completion of a Home (0) cycle. It deactivates automatically
with the next motion or when the Clear End Of Home input is used.
5 End Of Index Count
This output activates only after an index is executed the number of times specified by the
Index Count. It is deactivated automatically with the next motion or when the Clear End Of
Index Count input is used.
6 Hardware Fault
This output activates after the occurrence of a hardware drive fault. The specific hardware
fault is indicated by a character on the diagnostics display. It is deactivated when all hardware
faults are cleared.
7 Travel Limit Fault
This output activates when either a hardware or software travel limit is hit and is deactivated
when the fault is cleared. A Travel Limit fault will also cause an “L” to appear in the
diagnostic display.
8 Position Error Fault
This output activates whenever a Position Error Fault occurs and is deactivated when the fault
is cleared. Position Error (or following error) fault will cause an “F” to appear in the
diagnostic display (see “Troubleshooting” on page 145 for more details on Position Error).
9Home Completed
This output activates after the completion of a Home Cycle and stays active continuously
unless absolute position is lost.