Technical information
102
230V FX Series Positioning Drive Reference Manual
43 Time Base Override
Any motion initiated when this input is active will use the time base selected in the parameters
screen.
44 Clear Torque Limit
Output
Clears a Torque Limit Hit Output after a torque limit has been exceeded. Torque Limit Hit
Output is set up using the “Output Functions” screen.
50 Clear Position Window Timeout
This input is used to clear the Position Window Timeout output. The Position Window
Timeout Output will remain on until this function is activated.
Output Functions
This screen allows you to view or modify the Output Functions configuration of the drive.
The window on the far left corresponds directly with the Output lines on the drive. The next
window shows which output function is assigned to each line. The first column in the right
hand window shows each output function by number and description. The next column shows
which line each function has been assigned to. Output functions assigned to line 0 are
inactive.
Use the up/down arrow keys to move the cursor to the desired output function, type in the
chosen line number and press <Enter>. The output function number will now appear beside
the correct line number in the left window. The drive will accept multiple output assignments
on any output line.