20 Clear Sensor Limit Hit
Clears the Sensor Limit Hit output. The Sensor Limit is programmed by PCX or serial
commands. This input is used in “Feed to Sensor” and “Registration” indexes.
21 Reset Fault
Duplicates the function of the reset switch on the front of the digital drive. It will clear non-
fatal drive faults.
22 Zero Position
Sets the current position of the motor to zero. All absolute positions will be referenced to this
set position.
23 Zero Display
This function zeroes all position query commands (FP and CP), Absolute position is
unaffected.
24 Remember Position
Stores the current position of the drive in a Return absolute index. (Default = Zero). This
index number may be changes in the Suspend Function menu.
25 Return To Position
Returns to the position defined by Remember Position input. This input uses the Return index
which must be set up as an absolute index. This is an edge sensitive function. It must be taken
from low level to high level to be recognized.
26 Clear End Of Sequence
Clears the End Of Sequence output. If not assigned, the End Of Sequence output will
automatically clear when the next motion occurs. If this input is assigned, the output can only
be cleared by activating a “Clear end of sequence” input.
27 Clear Programmable Output
Clears a Programmable Output. Each assigned Programmable Output requires a separate
“Clear Programmable Output” line which corresponds to the PGO’s (output function #12) in
the same order. If four lines are selected for PGO’s, this input function requires four lines to
clear all of the PGO’s.