Technical information

96
230V FX Series Positioning Drive Reference Manual
12 Inhibit Drive
Prevents all motion by disabling the drive’s bridge transistors and engaging the holding brake.
The drive is re-enabled (and the brake is released) when input is removed.
13 Brake Override
Releases the brake when Inhibit is active. This allows the motor to be rotated by hand.
14 Index Select
Allows you to choose an index using input lines and sets the starting input line number for a
given number of index select lines. For example, if your system requires four index select
lines you could assign any four consecutive input lines. If you assigned the Index Select
function to input line #5, then entered a 4 as the number of Index Select Lines, the Index
Select function would now be assigned to input lines #5, 6, 7 and 8.
Decimal Binary Hexadecimal
000
111
2102
3113
41004
51015
6 110 6
71117
8 1000 8
9 1001 9
10 1010 0xA
11 1011 0xB
12 1100 0xC
13 1101 0xD
14 1110 0xE
15 1111 0xF
16 10000 0x10
32 100000 0x20
64 1000000 0x40
128 10000000 0x80