Technical information
95
Software Setup and Operation
4Jog
Starts and stops a jog in the direction specified by the Jog Direction input function #7.
Defaults to the programmed Jog Fast velocity.
5Jog +
Starts and stops a clockwise jog. If function input #8 is not assigned, the jog speed defaults to
the Jog Fast velocity.
6Jog -
Starts and stops a counterclockwise jog. If function #8 is not assigned, the jog speed defaults
to the Jog Fast velocity.
7 Jog Direction
Sets the direction for the Jog input function #4 (active = CCW).
8 Jog Slow
Causes the Jog Slow velocity to be used when Jog, Jog CW, or Jog CCW are executed. Jog,
Jog CW, or Jog CCW must be active before Jog Slow is executed.
9 Travel Limit +
Forces clockwise velocity to zero and inhibits any further clockwise motion.
Counterclockwise motion is allowed. The drive will display an “L” on the diagnostics
display. When released the “L” or travel limit is reset automatically.
10 Travel Limit -
Forces counterclockwise velocity to zero and inhibits any further counterclockwise motion.
Clockwise motion is allowed. The drive will display an “L” on the diagnostics display. When
released, the “L” or travel limit is reset automatically.
11 Stop Motion
Stops motion according to the Stop/Hold deceleration rate in the limits screen. A stop input
will terminate indexes, homes or programs (returning the drive to external control). Motion
resumes only if given another motion command. The stop input is active during all modes of
operation including serial mode.