Technical information

TROUBLESHOOTING 6-11
UGD001/1196 SC Carousel Dehumidifying Dryer
ADDING AN
AFTERCOOLER
You can add an aftercooler to the SC Carousel Dryer by order-
ing the optional aftercooler coils. Installation is easy.
The optional aftercooler requires a source of city, tower or
chiller water and a discharge or return line. You can use water
at temperatures up to 90˚ F (32˚ C). But the water flow should
be at least 3 gallons (11.36 liters) per minute.
Stop the dryer and dis-
connect power.
Remove the aftercooler
housing cover.
Insert the aftercooler
coils into the housing.
Make sure the latches on the
housing are aligned with the
latch holes in the aftercooler
coil lid.
Secure the latches.
Connect the cooler inlet
to the water source.
If a manual shut off valve is
used, it should be mounted on
the inlet line.
Connect the cooler out-
let to a discharge or
return line.
TIP:
Make the connections
with flexible hose at least
14 inches (35.5 cm) long.
This allows you to easily
remove the cooler coils for
cleaning.
1/2 inch NPT
female couplings
4
5
6
3
2
1
2
3
5
6