Stop the dryer.
Disconnect and lockout
the main power.
Remove the carousel
cover.
Loosen the screw on the limit switch bracket.
Slide the bracket left or right
to
position the limit switch so that its small
roller drops into the valley on the bed
plate. The roller should not hit the sta-
tionary bottom plate.
Test for correct indexing of the carousel.
Restore main power to the dryer. Hold the limit switch out
of the valley on the carousel bed plate while you flip the
toggle switch to START. Once the bed plate starts turning,
release the switch.
If everything is adjusted correctly:
◆ The carousel bed turns.
◆ When the limit switch reaches the next valley in the
bed plate, the carousel should stop turning.
Reset the desiccant carousel.
Continue indexing until the desiccant tanks return to the
positions they were in when the dryer shut down.
ADJUSTING THE
LIMIT SWITCH
3
4
180
180
1
2
Carousel
cover
5
6