User Guide Instruction Manual

52 - Chapter 2. Programming Interface DeviceMaster UP Modbus/TCP User Guide: 2000447 Rev. I
Port Object (F4 Hex - 1 instance)
2.3.6.4. Port Object (F4 Hex - 1 instance)
The Port Object enumerates the CIP ports on the DeviceMaster UP.
2.3.6.4.1. Class Attributes
2.3.6.4.2. Instance Attributes
2.3.6.4.3. Common Services
2.3.6.5. TCP Object (F5 Hex - 1 instance)
The TCP/IP Interface Object provides the mechanism to retrieve the TCP/IP attributes for DeviceMaster UP.
2.3.6.5.1. Class Attributes
Attribute ID Name Data Type Data Value(s) Access Rule
1Revision UINT 1 Get
2 Max Instance UINT 1 Get
3Num InstancesUINT 1 Get
8 Entry Port UINT 1 Get
9 All Ports Array of UINT
[0]=0
[1]=0
[2]=TCP_IP_PORT_TYPE (4)
[3]=TCP_IP_PORT_NUMBER(2)
Get
Attribute ID Name Data Type Data Value(s) Access Rule
1 Port Type UINT 4 (TCP/IP) Get
2 Port Number UINT 2 (TCP/IP) Get
3
Port Object
Structure of:
16-bit word count in path
Path
UINT
Array of UINT
2
[0]=0212 Hex
[1]=0
Get
Service Code Implemented in Class Implemented in Instance Service Name
01 Hex Yes Yes Get_Attribute_All
0E Hex Yes Yes Get Attribute Single
Attribute ID Name Data Type Data Value(s) Access Rule
1 Revision UINT 1 Get
2 Max Instance UINT 1 Get
3 Num Instances UINT 1 Get