Installation

Hardware Installation and Configuration Guide: 2000451 Rev. J Connecting Serial Devices - 47
Connecting Serial Devices
Serial Terminals (4) - 1E
This subsection discusses the following topics for the DeviceMaster UP 2-port 1E
with serial terminals (4). See Serial Terminals (8) - 2E
on Page 49 if the
DeviceMaster UP has eight serial terminals.
Serial Terminal (4) Connectors on Page 47
Serial Terminal (4) Null-Modem Cables (RS-232) on Page 48
Serial Terminal (4) Null-Modem Cables (RS-422) on Page 48
Serial Terminal (4) Straight-Through Cables (RS-232/485) on Page 48
Serial Terminal (4) Loopback Signals on Page 49
Connecting Serial Devices on Page 49
Serial Terminal (4)
Connectors
Use the following table or drawings for signal information. The signals for
SERIAL2 are the same as SERIAL1.
RS-232† TxD RTS RxD CTS
RS-422/RS-485
Full-Duplex
TxD- TxD+ RxD- RxD+
RS-485
Half-Duplex
TRxD- TRxD+
RS-232 ground must be connected to the appropriate signal ground
terminal.
CTSRxDRTSTxD
RS-232
RxD+
RxD-
TxD+
TxD-
RS-422
RS-485 Full-Duplex
TRxD+
TRxD-
RS-485 Half-Duplex
RS-232 ground must be connected to the appropriate signal ground
† Wire gauge: AWG 12-22
Signal
Ground
Not connected
Positive†
Return†
5-30VDC
Signal
Ground†
Chassis
Ground†
RS-232: Connecting the Ground