Installation
Hardware Installation and Configuration Guide: 2000451 Rev. J Hardware Installation - 17
Hardware Installation
Mounting the
Embedded
Use the following procedure to mount the DeviceMaster UP 1-Port Embedded with
the 5-30VDC power supply.
Observe proper ESD techniques when handling the DeviceMaster UP.
1. Carefully remove the DeviceMaster UP from the anti-static bag, following
standard electrostatic device handling procedures.
2. Mount the DeviceMaster UP for your environment using 1/4” stand-offs to
separate the DeviceMaster UP from the base.
3. Use one of the following methods to ground the DeviceMaster UP.
• Through the power supply by connecting the ground wire on the power
cable using plastic or metal stand-offs.
• Through the chassis, using metal stand-offs. If plastic stand-offs are used
to mount the board, then you must ground the DeviceMaster UP using the
power cable.
Note: The maximum diameter of the metal stand-offs should be 0.175” with a
4-40 machine screw. Metal stand-offs are not provided with the
DeviceMaster UP.
4. Optionally, attach the light pipes. The following light pipes have been tested
and found to function; Bivar, Inc. (P/N:LP-230) and Ledtronics, Inc.
(P/N:LTP003-0CW-001).
Caution
Non‐plated/non‐groundedmountingholes0.116”diameter(+/‐0.003”).
WARNING:Holesinhatchedareaarenotmountingholes.
Maximumcomponentheightaboveboardis0.55”.
EthernetconnectionJ2:J2overhangsboardedgeby0.14”andtheheightis0.55”.
LEDlightpipemountingholes.TheLEDlightpipesarenotprovided.
SerialportconnectorJ3:0.1”pinspacing,0.025”squarepindiameter,and0.230”
pinheight.
DebugportconnectorJ4:0.1”pinspacing,0.025”squarepindiameter,and0.230”
Powerconnector;thematingconnectorisWeidmullerP/N:152651.
1
3
4
5
6
7
8
9
Plated/chassisgroundedmountinghole0.116”diameter(+/‐0.003”).
2
pinheight.
5-30VDC Model
Caution