User guide
Table Of Contents

4 Installing the DeviceMaster 500 and the SICK LMS Scanner (Windows): 2000472 Rev. C
1-Port Custom Embedded Bulk (99474-9) Installation
Go to Software Installation on Page 9 to complete the installation.
1-Port Custom Embedded Bulk (99474-9) Installation
Use the following procedure to set up the 1-port custom embedded bulk
DeviceMaster 500 and LMS scanner at 500K baud.
• If necessary, build the serial ribbon cable.
• Mount the DeviceMaster 500 and optionally install light pipes (Page 5).
• Attach the network and serial cables (Page 6).
• Connect the power and verify installation (Page 7).
Building the Serial
Ribbon Cable
Use the following information to build a DB9 serial ribbon cable to connect to the
DeviceMaster 500 1-Port embedded IDC10 connector (J3).
Status
If the LED is lit, it indicates that the DeviceMaster 500 has
power and it has completed the boot cycle.
Note: The Status LED flashes while booting and it takes
approximately 15 seconds for the Bootloader to
complete the boot cycle. When the Bootloader
completes the cycle, the LED has a solid, steady light
that blinks approximately every 30 seconds.
LED Descriptions 1-Port Enclosed
J3 Header RS-232 RS-422 RS-485
1 CD Not used Not used
2 DSR Not used Not used
3 RxD RxD- Not used
4 RTS TxD+ TRX+
5TxDTxD-TRX-
6CTSRxD+Not used
7 DTR Not used Not used
8 RI Not used Not used
9 GND Not used Not used
10 Not connected
Pin 1
Pin 6
1
2
9 10
Ribbon Cable
10-Pin
Socket
Pin 5
Pin 9
DB9
Male
J3