Owner manual

IO-Link Master EtherNet/IP Reference Manual: 2000589 Rev. A Chapter 1. EtherNet/IP Interface - 15
Output Process Data Block Description
1.3.2. Output Process Data Block Description
The contents of the Output Process Data Block are configurable.
1.3.2.1. Output Process Data Block-8 Bit (SINT) Data Format
With the Include Event to Clear option selected:
Without the Event to Clear option selected:
1.3.2.2. Output Process Data Block-16 Bit (INT) Data Format
With the Include Event to Clear option selected:
Parameter Name Data Description
Event to Clear
(Configurable option)
Default: Not included
INT
If included, allows clearing of 16-bit event code received in
the PDI data block via the PDU data block.
PDO Data
Default Length = 32 bytes
Array of up
to 32 BYTEs
The PDO data written to the IO-Link device. May contain
from 0 to 32 bytes of PDO data. The definition and length
of the PDO data is device dependent.
Note: Length is configurable via web page interface.
Byte Bit 7 Bit 0
0 Event Code LSB
1 Event Code MSB
2 PDO Data Byte 0
3 PDO Data Byte 1
.. ..
.. ..
N+1 PDO Data Byte (N-1)
Byte Bit 7 Bit 0
0 PDO Data Byte 0
1 PDO Data Byte 1
.. ..
.. ..
N-1 PDO Data Byte (N-1)
Word Bit 15 Bit 0
0 Event Code
1 PDO Data Word 0
2 PDO Data Word 1
.. ..
.. ..
N PDO Data Word (N-1)