User Manual

20 - Hardware Installation DeviceMaster Installation and Configuration Guide: 2000594 Rev. A
Hardware Installation
4. Optionally, attach the light pipes. The following light pipes have been tested
and found to function; Bivar, Inc. (P/N:LP-230) and Ledtronics, Inc.
(P/N:LTP003-0CW-001).
After mounting the DeviceMaster, you are ready to connect the cables.
Attaching the
Network and Serial
Cables
Use the following procedure to attach the serial ribbon and Ethernet cables. For a
larger illustration of the system, see 1-Port Embedded on Page 144.
1. Attach the ribbon cable built in Building the Serial Ribbon Cable on Page 18
to the header labeled J3.
2. Connect a standard Ethernet cable from the RJ45 port on the DeviceMaster to
your Ethernet hub.
The default serial port setting on the DeviceMaster is RS-232. Do not
connect the serial device until you have configured the serial port
settings. You must configure network settings and upload firmware
before configuring the serial port settings.
Use the next subsection to wire the power terminal connector and verify the
hardware installation.
Connecting the
Power and Verifying
Installation
Use the following procedure to wire the power terminal connector and connect the
DeviceMaster to a power source.
Observe proper ESD techniques when connecting and disconnecting
the DeviceMaster.
1. Insert the earth ground wire into the earth ground screw terminal.
2. Insert the DC positive wire into the
positive screw terminal and the DC return
wire into the return screw terminal.
If you purchased the Comtrol power
supply (separately), the wires are
identified below:
Red = 5-30VDC positive
White = 5-30VDC return
Black = earth ground
If you did not purchase a power supply
from Comtrol for the DeviceMaster, see
1-
Port 5-30VDC Power Supply on Page 138
for power requirements.
Ethernet
10/100
Connector
J3
12
910
Caution
Caution
Earth Gnd
Return
Positive
5-30VDC
+
-
Wire gauge:
AWG 12-22
Screw Terminal Power Connector