Specifications
Limit Switches
5--122
Visit our website: www.ab.com/catalogs.
Preferred availability cat. nos. are printed in bold.
The 30mm metal safety limit switches
conform to EN 50041 and have been
developed to provide a range of options
including metal or plastic cases in
various sizes, a choice of snap acting,
slow break/make with 2, 3 or 4 contact
configurations and a choice of actuator
heads. The distance between the
horizontal mounting holes is 30 mm.
The Senator range offers the option of
rotating the head in 90q increments
before installation to allow ease of
mounting.
Allen--Bradley/Guardmaster limit
switchescanbeusedinother
applications other than guard doors, for
example on moving machine beds,
crane arms, lifts, elevators, etc.
Operation of these limit switches is
achieved by the sliding action of the
guard or other moving object deflecting
the plunger or lever.
A
TTENTION
For safety applications
it is important that
upon actuation, the
guard or other moving
objects should not
pass completely over
the switch and allow
the plunger or lever to
return to its original
position.
Specifications
Features
S Large selection of actuator heads
S Positive operation, forced
disconnection of contacts
S Snap-acting, slow make before break
or slow break before make contact
blocks
S Contacts 1 N.C. + 1 N.O., 2 N.C. +
1 N.O. 3 N.C., 2 N.C. + 2 N.O.,
3 N.C. + 1 N.O., or 4 N.C.
S Conforms to EN 50041, EN 1088, EN
60947--5 --1, EN 292 and EN
60204--1
Safety Limit Switches
Product Selection page 5--123........
Wiring page 5 --126..................
Dimensions page 5--126.............
440P Safety Limit Switches
30mm Metal Position Switches
EN954--1, ISO13849--1, IEC/EN60204--1, NFPA79, EN1088, ISO14119,
IEC/ EN60947--5--1, ANSI B11.19, AS4024.1
Cat. 1 Device per EN954--1 Dual channel interlocks suitable for Cat. 3 or 4
systems
cULus, TÜV, CE and CCC Marked for all applicable directives
1 N.C. snap acting, 2 N.C., 3 N.C. or 4 N.C. slow acting
1 N.O. (with 2 N.C.)
600 V 500 V 240 V 120 V
1.2A 1.4A 3A 6A
600 V 500 V 250 V 125 V
0.1 A 0.13 A 0.27 A 09.55 A
5V,5mA,DC
8A
600VAC
2500 V
Various (see Product Selection table)
250 mm/s
100 mm/min
6000 operation per hour
Die cast alloy
See Product Selection table
IP66
Min --25qC(--18qF) Max 80qC (+176qF)
3
1 x 107
M20or1/2inchNPT
2xM5
Any position
Red
Standards
Category
Approvals
Safety Contacts
Auxiliary Contacts
Designation/Utilization Cat.
A600/AC- 15 (Ue)
(Ie)
Q600/DC- 13 (Ue)
(Ie)
Min Current
Thermal Current (lth)
Rated Insulation Voltage
Rated Impulse withstand Volt
Travel for Positive Opening
Max Switching Speed
Min Switching Speed
Max Switching Frequency
Case Material
Actuator Material
Enclosure Protection
Operating Temperature
Pollution Degree
Mechanical Life Expectancy
Conduit Entry
Fixing
Mounting
Color
Conductive pollution occurs, or dry, nonconductive pollution occurs which becomes conductive due to condensation.