Instruction Manual

DeviceMaster Primo for Pair and Raw Connect Methods 22
UDP Client
Note: The Connection Status states that the device is transmitting.
13. Press the Enter key to return to the main menu. Select the Restart menu
item to restart and save the changes.
14. You have to repeat this procedure for each client device.
UDP Client Setting the parameters for a UDP Raw Connection requires two procedures.
Follow the UDP Server procedure first then complete the following UDP Client
procedure.
1. From the Start menu, select the Run command.
2. Type Telnet plus the first client Primo IP address and select the OK button.
You have to repeat this procedure for each client device.
3. Confirm that it is a vt100 session, and press the Enter key.