Manual
AT Commands for CX81801/CX06833/CX81300/CX06827 Modems Reference Manual
Conexant 102184B
3-50
–STE= - Set Telephony Extension
The –STE command enables/disables Line In Use, Extension Pickup, and Remote
Hangup detection features.
Note: Additional hardware may be required to support these features.
Syntax
-STE=<value>
Defined Values
<value> Decimal number corresponding to the selected bit-mapped
options. The bit fields are defined as follows:
Bit 0 Line In Use detection enable/disable.
Bit 1 Extension Pickup detection enable/disable.
Bit 2 Remote Hangup detection enable/disable.
<value>
(Dec.)
Remote
Hangup
Extension
Pickup
Line In Use
0 (default) Disabled Disabled Disabled
1 Disabled Disabled Enabled
2 Disabled Enabled Disabled
3 Disabled Enabled Enabled
4 Enabled Disabled Disabled
5 Enabled Disabled Enabled
6 Enabled Enabled Disabled
7 Enabled Enabled Enabled
Reporting Current or Selected Values
Command: -STE?
Response: -STE: <value>
Example: -STE: 4 Remote Hangup enabled, Extension
Pickup disabled, and Line In Use
disabled.
Reporting Supported Range of Parameter Values
Command: -STE=? Show available options.
Response: -STE: 0-7
Result Codes
OK <value> = 0-7
ERROR Otherwise.