User guide

VMS Network Configuration
3-12 VMS User Guide
Setting the Alarm Masks
Network alarms must be set to insure an alarm alerts the operator to an actual
problem. If there are spurious alarms, or alarms which have no operational
meaning the operator will become desensitized and critical network failures can
be missed. This section addresses masking alarms that represent normal
network conditions. VMS allows the masking of these nuisance alarms. Do not
skip this step if you want your operators to manage the network pro-actively and
respond quickly to alarms.
In a Vipersat network, there are burst controllers that are locking and unlocking
multiple times per second, and expansion units whose normal parked or quies-
cent state is to be unlocked. Perform the following procedure for all network
units that function as either a Burst Controller or an Expansion unit.
Note: On SLM-5650A modems, masking is pre-configured when set to Hub
and Selective TDMA is enabled.
1.
From the Tree View, select the unit and open the Properties window as shown
in figure 3-10.
For CDM-570/570L and CDD-56X units, right-click on the unit icon and
select Properties from the drop-down menu.
For SLM-5650A units, right-click on the demodulator icon and select
Properties from the drop-down menu.
2. Select Mask Unlock Alarm, then click on OK.
3. Right-click on the unit’s icon again and select Force Registration to activate
the flag.