User guide
N:M Hub Modem Redundancy
C-38 VMS User Guide
Figure C-39
BUC configuration, CDM-570/570L
11. Disable the Satellite Modem > Configuration > Configuration > Low Noise
Block Converter (LNB) LNB DC Supply Voltage as shown in figure C-40.
Figure C-40
LNB configuration, CDM-570/570L
12. This completes the process of setting the VMS controlled modem to parked
configuration mode and it now ready to be put back into service.
13. If the repaired unit is to be connected to the same plug, it will automatically
reinstate the unit as a member of the backup group. VMS identifies the unit
by its MAC address so if, for any reason, the failed unit is replaced with
another unit, you will have to go to VMS and drag the newly installed unit to
the appropriate plug on the power strip to complete its installation.
Caution: Failure to follow the discipline of connecting the repaired unit to the
correct plug on the remote controlled power strip will result in the unit
not being able to be turned off if it fails while acting as the primary
unit, resulting in the possibility of having two active units trying to
operate in the same role and consequently crashing the network.