User guide

Appendix C - Redundancy C-13
N:M Hub Modem Redundancy
N:M Hub Modem Redundancy
Description
The N:M Hub Modem Redundancy service provides for the protection of criti-
cal VMS network modems operating in Hub mode and enhances overall
network reliability.
The N:M redundancy in VMS version 3.x has the following characteristics:
Protects Vipersat Hub modems from equipment failure
Is a VMS controlled feature
Does not require any external switching hardware
Preserves the satellite network configuration and state information during
hardware failure
Is scalable and flexible to satisfy the unique requirements of each network
N:M redundancy increases reliability by backing up critical primary central hub
components with standby backup units. In a traditional 1:1 or 1:N redundancy,
switching is handled by combining transmission equipment into logical
mechanical switching units. These software/hardware units then interconnect
the primary transmission units I/O through a physical mechanical maze of
relays and cable jungles. They also become the next point of failure in the reli-
ability hierarchy.
The Vipersat solution relies less on a mechanical backup system architecture,
decreasing the single point of failure. The Vipersat software-driven N:M redun-
dant architecture is completely IP packet controlled with the only hardware item
being an IP controlled electrical power switch.