User guide

Chapter 6 - Out-of-Band Units 6-1
C
HAPTER
OUT-OF-BAND UNITS
General
This chapter describes integrating out-of-band units into a VMS-controlled
satellite network.
Controlling Non-IP Modems
Before VMS can communicate with a non-IP capable modem, the modem must
have an IP-addressable unit, such as the Comtech CiM-25/600 or CiM-25/600L
attached and assigned a valid IP address using procedures described in the
appropriate product documentation, and described in the following procedure.
Modems such as the CDM-700, SLM-5650 or CDM-570 have a built-in Ether-
net interface and do not require an external CiM unit. Refer to these unit’s docu-
mentation for the procedure for assigning a valid IP address to the unit.
Note: Check the unit’s documentation for specific, detailed procedures.
Once a valid IP address has been assigned to target CiM-25, install the CiM-25
on its companion CDM-600L. The modem must then be declared in VMS using
the following procedure.
1. Connect the target CiM-25 unit to your workstation and assign a valid IP
address for the network where the CiM-25 and its companion CDM-600L
are to be installed
2. Reconnect the CiM-25 to its companion CDM-600L, then connect the eth-
ernet LAN and apply power as required.
NOTE