Product specifications

4–4
AGILE DOC ID ER-MNCDD564L.EA1 THIS DOCUMENT IS NOT SUBJECT TO REVISION/UPDATE! AGILE CO11666
5
Confirm that the files have been extracted to the specified temporary folder on the PC. In DOS,
use cd c:\t e m p to change to the temporary directory created in S t e p 2 , then use the dir
command to list the files extracted from the downloaded archive file.
4.4 Base Unit Bulk Firmware Upgrade Ethernet FTP Upload Procedure
Step
Procedure
6
Connect the external PC to the CDD-562L/564’s 10/100 Ethernet M&C port via a hub or a
switch, or directly to a PC with a crossover cable.
7
Send a “ping” command to the demodulator to verify the communication and connection.
Determine the IP address of the demodulator either remotely or by using the front panel:
U si ng D OS t o p in g: Click S t ar t on the Windows toolbar, then select the Run... option.
(Alternately, use the D OS Pr om pt o rCommand Prompt icons in the Start Menu. )
Using Win95 or Win98: T ype c o mma n d.
Using WinNT, Win2K or WinXP: Type cmd.
Once in DOS, use cd c:\temp to change to the temporary directory created earlier in Step
2. Use the “dir command to list the downloaded files.
8
Initiate an FT P sess ion with the demodulator (this exam ple uses a DO S win dow):
a) From the PC, type "ftp xxx.xxx.xxx.xxx" where xxx.xxx.xxx.xxx’ is the IP address of
the CDD-562L/564.
b) Enter the Admin User Name and Password to complete login.
c) Verify the FTP transfer is binary by typing "bin".
d) Type "prompt", then type "hash" to facilitate the file transfers.
9
Transfer the files from the temporar y folder on the PC:
Type "put FW#######x.bin" (where #######is the designated firmware file number, and
‘xis the revision letter) to begin the file transfers.
The process sequences through several blocks this may take several minutes. When the
upgrade image has been received, the image will be written to flash memory.
10
Change the desired image to boot. By default, the demodulator will boot to the version with
the latest date (Boot to Latest).
Boot to can also be set to force the demodulator to boot up using either Image #1 or
Image #2. The unit will then need to be reset (i.e., rebooted or power cycled) from the serial
console, Web Server Interface, or CLI/Telnet for the firmware upgrade selection to become
active:
To reset from the Web Server Interface, select the M a in t | R e bo ot pa g e, then click [Yes,
R eb oo t ] .
To reset from the CLI/Telnet Main Menu, select O pe r at io n s a n d M a in t en a nc e [ O] , then
select Reset [R].
Errata Page 6 of 6