D.4.1.6 Redundancy Query
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Redundancy
State
N/A 1 byte, value
of 0 or 1
Query only.
Returns the redundancy state of the unit, where
0 = Offline
1 = Online
Example: RED=1 (which is Online)
N/A RED? RED=x
(see description
of arguments)
D.4.1.7 Routing Commands and Queries
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Route Table Get N/A N/A Query only.
Gets the whole Routing Table of the modem.
Each route entry is separated by ‘\r’ [chr(13)]
Notes:
The route table will be displayed only if system’s working mode is “Router
–Small, Router-Large, Router-PtP.
If the system is in EasyConnect mode, it may return RCG!
RCG! RCG? RCG=
xxxxxxxxxxxxxx
xxxxxxxxxxxxxx
Delete route
entry
RTD= RTD=4 bytes,
numerical
Command Only.
Deletes the route entry at the specified index number, if configured.
Note: Returns RTD! if there is no route at the index.
RTD =
RTD! RTD=xx.xx
(see description of
arguments)
Number of route
entries
N/A RTN=3 bytes,
numerical
Query Only.
Returns the number of route entries in the route table.
Note: This command should be issued whenever a new route is
added/deleted.
RTN =
RTN!
RTN? RTN=xxxx
(see description of
arguments)