Product specifications

CDD-562L/564 Demodulator with IP Module Revision 2
Rear Panel Connections MN/CDD564L.IOM
3–9
3.3.3 48V Direct Current (DC) Power Interface (Optional)
Figure 3-6. CDD-56X DC Power Interface
3.3.3.1 DC Operation – Applying Power
Figure 3-7. Applying DC Power to the CDD-56X
ToapplyDCpowertotheCDD56X:
First, assemble the usersupplied red(+)and black (–) DC power leadsand their crimped
terminalsintotheshellofthemodulematingconnector.Number18AWGminimumwires
arerecommended.Notethekeyedorientationforthewires.
Then,connec
ttheusersuppliedDCpowerleadstothepowersource.
Finally,plugtheconnectorintothekey edmodulesocketasshown.
Feature Description
1 On / Off Switch
2 Plug-in Power Receptacle
DC Power Specifications
Input Power 48 watts (typical)
55 watts (maximum)
Input Voltage 48 volts DC nominal
(36 volts to 60 volts)
Connector Type Corcom PS series
Mating Connector Corcom GA210 or Molex 03-12-1026
Fuse Protection
Line and Neutral Fusing
(2X) 5mm x 20mm Slow-blow type fuses:
T8A (8 Amp)