Product specifications

CDD-562L/564 Demodulator with IP Module Revision 2
Rear Panel Connections MN/CDD564L.IOM
3–8
3.3.2.2 AC Operation – Replacing Fuses
The CDD-56X uses two 5mm x 20mm Slow-blow fuses – one each for line and neutral
connections. The fuses are contained within a fuse holder that is press-fit into the body of the IEC
power module (located on the rear panel, Figure 3-5).
Figure 3-5. Replacing CDD-56X AC Fuses
To replace the fuse(s):
DISCONNECTTHEPOWERSUPPLYBEFOREPROCEEDING!
First, unseat the fuse holder from the IEC power module.
o Use the slot to pry the holder outward from the IEC power module.
o Pull the holder straight out, and then swing the holder away from the module.
Then, remove and replace the T3.15A (3.15 Amp) fuses as needed.
FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES WITH THE
CORRECTTYPEANDRATING.
Finally, re-seat the fuse holder in the IEC power module.