Product specifications
CDD-562L/564 Demodulator with IP Module Revision 2
CDD-56X CLI and Telnet Operation MN/CDD564L.IOM
8–32
8.2.7.1.3 LNB Configuration (Per LNB) page
Access the LNB Configuration (Per Demod) page from the Configuration page. Note that all
parameters on this page are configurable on a per-LNB basis (as determined via Demod Select).
This page contains the following unique selections/fields:
Selection Entry Description
LNB DC Supply Voltage P Select as [On] or [Off].
LNB 10MHz Reference Enable R Select as [On] or [Off].
LNB Current Alarm Lower Limit (mA) C Valid range is from 10 to 400 mA.
LNB Current Alarm Upper Limit (mA) H Valid range is from 50 to 600 mA.
LNB LO Frequency (MHz) L Valid range is from 3000 MHz to 65000 MHz.
LNB Current [RO]
Displays active LNB current values on a per-LNB basis, when
the presence of an LNB is detected.
LNB Voltage [RO]
Displays active LNB voltage values on a per-LNB basis, when
the presence of an LNB is detected.