User guide
Initial Configuration
2-10 Vipersat CDD-56X Series User Guide
2. Enter R to access the Rx Configuration screen shown in figure 2-8. Set
the Rx parameters for Frequency, Data Rate, FEC, Code Rate, and
Modulation as specified by the network administrator.
The Receive parameters must be set for each Demod. Enter Z at the com-
mand prompt to select the desired Demod, then set the Receive parameters
for that Demod. Repeat for each Demod.
Note: Only Turbo Product Coding is acceptable for FEC when the CDD-56X is
running in Vipersat mode.
Figure 2-8
Rx Configuration screen
3. Save the settings to flash by entering S at the command prompt.
Set the Vipersat Configuration
1. Enter V at the Main Menu command prompt (figure 2-1) to select the
Vipersat Configuration menu shown in figure 2-9.