Product specifications

UT4500 Series Up Converter MN/UT4500.IOM
Remote Control Revision 2
58
5.2.2 BAUD RATE
The default serial port Baud Rate is 9600. Baud rates of 1200, 2400, 4800, 19200, and
38400 are also supported.
5.2.3 FORMAT
The following parameters are the default character format.
1 Start Bit
8 Data Bits
No Parity Bit
1 Stop Bit
5.2.4 CHARACTER SET
The character set implemented is ASCII.
5.2.5 RESPONSE TIMEOUT
A minimum of 500 milliseconds should be provided before declaring a ‘no response’
instance, at which time the command should be re-transmitted.
5.2.6 BUS INACTIVITY REQUIREMENT
Comtech EF Data recommends that a minimum of 50 milliseconds bus inactivity be
provided by the user between the receipt of a response from an addressed converter and
issuing the next command on the serial bus.