Product specifications

UT-4500-A Series Upconverters Revision 0
Appendix A MN-UT4500A
A–9
A.7.1.7 Physical Address
The default physical address is 001.
Command Details
Set Physical Address: <DEV/SPA_xxx'cr' xxx = 1 to 255
Confirmation: >DEV/SPA_xxx'cr''lf']
Retrieve Phys. Addr: <DEV/SPA_'cr'
Confirmation: >DEV/SPA_xxx'cr''lf']
A.7.1.8 Baud Rate
The default baud rate is 9600.
Command Details
Set Baud Rate: <DEV/SBR_xxxx'cr' xxxx = 1200, 2400, 4800, 9600, 19K2, or 38K4
Confirmation: >DEV/SBR_xxxx'cr''lf']
Retrieve Baud Rate: <DEV/SBR_xxxx'cr'
Confirmation: >DEV/SBR_xxxx'cr''lf']
A.7.1.9 LCD Contrast
This legacy command does not control any hardware, but its syntax is still supported to allow
backwards compatibility with existing monitor and control applications. The default LCD
contrast is 15.
Command Details
Set Contrast: <DEV/CON_xx'cr' xx = 0 to 30
Confirmation: >DEV/CON_xx'cr''lf']
Retrieve Contrast: <DEV/CON_'cr'
Confirmation: >DEV/CON_xx'cr''lf']
A.7.1.10 LCD Brightness
This legacy command does not control any hardware, but its syntax is still supported to allow
backwards compatibility with existing monitor and control applications. The default LCD
brightness is 15.
Command Details
Set Brightness <DEV/LCD_xx'cr' xx = 0 to 30
Confirmation: >DEV/LCD_xx'cr''lf']
Retrieve Brightness: <DEV/LCD_'cr'
Confirmation: >DEV/LCD_xx'cr''lf']