Product specifications

UT-4500-A Series Upconverters Revision 0
Flash Upgrading MN-UT4500A
4–3
4.3 Ethernet FTP Upload Procedure
Step Procedure
1
Identify the reflashable product, firmware number, and version for download.
The current unit M&C version can be viewed at the top-level menu of the front panel display
(press the [CLR] key several times to view). The firmware information can also be found
within the UTILITY ! FIRMWARE! INFO ! IMAGE#1 or IMAGE#2 menu branches.
Using serial remote control, the firmware revision levels may be obtained with the <1/FRM?
query. For more information, refer to Appendix A. REMOTE CONTROL.
2
Create a temporary folder (directory) on an external PC:
! For Windows Explorer: Select File > New > Folder to create a new folder, then
rename it fromNew Folder to "temp" or another convenient, unused name. Assuming
"temp" works, a "c:\temp" folder should now be created.
Note: The drive letter c: is used in this example. Any valid writable drive letter can be
used.
! For Windows Command-line: Click [Start] on the Windows taskbar, then click the
Run...icon (or, depending on Windows OS versions prior to Windows 95, click the
MS-DOS Prompt” icon from the Main Menu). Then, to open a Command-line
window…
o For Windows 95 or Windows 98 Type “command”.
o For any Windows OS versions later
than Windows 98 Type cmd or
command”.
o Alternately, from [Start], select All Programs > Accessories > Command
Prompt.
At the Command-line prompt (c:\>), type mkdir tempor “md temp (without quotes – mkdir
and md stand for make directory). This is the same as creating a new folder from Windows
Explorer. There should now be a "c:\temp" subdirectory created (where c: is the drive letter
used in this example).