Product specifications
UT-4500-A Series Upconverters Revision 0
Appendix A MN-UT4500A
A–21
A.7.4.9 Packed Utility Status
Packed Utility Status: <DEV/PACRUS_'cr'
Confirmation: >DEV/PACRUS_abbcdeeffghhii'cr''lf']
where:
a = 0=EIA-232, 1=EIA-485
bb = Address in hex (01 to FF)
c = 0 if Baud Rate 38400
= 1 if Baud rate 19200
= 2 if Baud rate 9600
= 3 if Baud rate 4800
= 4 if Baud rate 2400
= 5 if Baud rate 1200
d = 0 if Data Format 8-N-1
= 1 if Data Format 7-E-2
= 2 if Data Format 7-O-2
ee = Osc. Adjust in hex (00 to FF)
ff = Slope Adjust times by 10 (00 to 10)
g = Always 0, unused
hh = LCD Contrast (0 to 30)
ii = LCD Brightness (0 to 30)
A.7.4.10 Packed Alarm Status
Packed Alarm Status: <DEV/PACRAS_'cr'
Confirmation: >DEV/PACRAS_abcdefghijk'cr''lf']
where:
a = 1 if V15 Fault, else 0
b = 1 if V14 Fault, else 0
c = 1 if VCC Fault, else 0
d = 1 if V5D Fault, else 0
e = 1 if TEMP Fault, else 0
f = 1 if IFLO Fault, else 0
g = 1 if SUM Fault, else 0
h = 1 if COARSE Fault, else 0
I = 1 if FINE Fault, else 0
j = 1 if HSB Fault, else 0
k = 1 if EXT REF Fault, else 0