11.4.3.4 Configuration #4 (Local EIA-485 [4-Wire] to Remote EIA-232)
Table 11-6. Local EIA-485 (4-Wire) to Remote EIA-232
#4. Local End Modem Settings for EIA-485 (4-Wire)
Utility Interface Menu
ASYNC TX and RX Type EIA-485 (4-wire)
Configuration Interface Menu
ASYNC TX and RX Baud Rate 110 to 38400 (See A.4.6)
ASYNC TX and RX Length 7 bits
ASYNC TX and RX Parity Even
ASYNC TX Stop 2 bits
#4. Remote End Modem Settings for EIA-232
Utility Interface Menu
ASYNC TX and RX Type EIA-232
Configuration Interface Menu
ASYNC TX and RX Baud Rate 150 to 38400 (See A.4.6)
ASYNC TX and RX Length 7 bits
ASYNC TX and RX Parity Even
ASYNC TX Stop 2 bits
Utility System Menu
Remote Baud Rate Equal to ASYNC TX and RX baud rate
Parity Even
Address 1 to 255
The local end cable connects the 25-pin female ASYNC connector (on either the
breakout panel or the Y cable) to the EIA-485 (4-wire) remote terminal (WYSE or laptop
computer). The pinout of the local cable is listed in the following table.
#4. Local End EIA-485 (4-Wire) Twisted Pair
9-Pin
Female Connector
25-Pin
Male Connector
TX+ 4 14 TX+
TX- 5 2 TX-
RX+ 8 16 RX+
RX- 9 3 RX-
The remote end cable connects the 25-pin female ASYNC connector (on either the
breakout panel or the Y cable) to the 9-pin female connector, J6, at the rear of the
modem. The pinout of the remote cable is listed in the following table.
#4. Remote End EIA-232
9-Pin
Male Connector
25-Pin
Male Connector
RX 2 2 RX
TX 3 3 TX
GND 5 7 GND