Specifications

SDM-300L3 Satellite Modem Revision 0
Front Panel Operation MN/SDM300L3.IOM
4–113
FUNCTION SELECT: UTILITY: MODEM TYPE:
LOCAL MODEM AUPC
LOCAL MODEM AUPC
OFF
Selecting Local Modem AUPC = ON enables the Configuration: Local AUPC: menu
where programming for self-monitoring AUPC with one modem or remote AUPC
between two modems is performed. These modes automatically adjust the TX Power
Level from the modulator to compensate for rain fades.
The self monitoring does not require the ASYNC/AUPC option and the Overhead card to
be installed or the AUPC Option and Reed-Solomon cards installed to operate.
AUPC between two modems does require either the ASYNC/AUPC option and the
Overhead Card or the AUPC option and the Reed-Solomon cards.
Notes:
1. When the Overhead card with the ASYNC/AUPC option is installed, and the
self-monitoring Local Modem AUPC mode is needed, do not select ASYNC as
the Modem Type.
2. When the Reed-Solomon card with AUPC option is installed, select AUPC from
the Modem Type menu (under Utility: Modem Type menu) when AUPC between
two modems is needed.
3. The Modem must be configured for Duplex operation and the demodulator
locked to the modulator signal.
FUNCTION SELECT: UTILITY: MODEM TYPE: MODEM SERIAL #
MODEM SERIAL #
012345678
Status Only.
Displays the modem serial number.