Specifications
SDM-300L3 Satellite Modem Revision 0
Front Panel Operation MN/SDM300L3.IOM
4–51
4.6.2 FUNCTION SELECT: MONITOR
FUNCTION SELECT
MONITOR
Press <ENTER > to review or edit the following sub-menus.
FUNCTION SELECT: MONITOR: RAW BER
RAW BER
2.4 E-3
Displays the current BER or “No Data” (if carrier is not locked).
Range: < m.m E-e to > m.m E-e.
Notes:
1. Low limit is based on performance.
2. High limit is based on data/code rate.
Press[←] or [→] to move the flashing cursor, and [↑] or [↓] to increment or decrement
the selected kbps. Press <ENTER> to execute the change.
FUNCTION SELECT: MONITOR: CORRECTED BER
CORRECTED BER
4.0 E-3
Displays the current corrected BER or “No Data” (if carrier is not locked).
Range: 1.0 E-3 to 1.0 E-12.
Notes:
1. Low limit is based on performance.
2. High limit is 1.0 E-12.
Press[←] or [→] to move the flashing cursor, and [↑] or [↓] to increment or decrement
the selected kbps. Press <ENTER> to execute the change.