Specifications
Remote Control Operation SDM-650B Satellite Modem
B–66 Rev. 6
B.2.8.16.3 Common Equipment Stored Faults
Command: <add/CSF_#”cr”
Response: >add/CSF_# hh:mm:ss MM/DD/YY”cr”
M&C_xxx”cr” Monitor and Control Module (OK/FLT)
INT_xxx”cr” Data Interface Module (OK/FLT)
BAT_xxx”cr” Battery (OK/FLT)
PS1_xxx”cr” +5V Power Supply (OK/FLT)
PS2_xxx”cr” +12V Power Supply (OK/FLT)
PS3_xxx”cr””lf”] -12V Power Supply (OK/FLT)
B.2.8.16.4 Interface Transmit Side Stored Faults
Command: <add/ITSF_#”cr”
Response: >add/ITSF_# hh:mm:ss MM/DD/YY”cr”
CLK_xxx”cr” Selected Transmit Clock Activity
(OK/FLT)
PLL_xxx”cr””lf”] Transmit Synthesizer PLL Lock
(OK/FLT)
B.2.8.16.5 Interface Receive Side Stored Faults
Command: <add/IRSF_#”cr”
Response: >add/IRSF_# hh:mm:ss MM/DD/YY”cr”
MUX_xxx”cr” MUX Lock (OK/FLT)
CLK_xxx”cr” Selected Buffer Clock Activity
(OK/FLT)
PLL_xxx”cr” Receive Synthesizer PLL Lock
(OK/FLT)
(See Note) OVFL_xxx”cr” Buffer Overflow (OK/FLT)
(See Note) UNFL_xxx”cr””lf”] Buffer Underflow (OK/FLT)
Note: Available with buffer support hardware only.