Specifications
SDM-650B Satellite Modem Remote Control Operation
Rev. 6 B–53
B.2.7.1.7 AUPC Local Carrier Loss Action
Command: <add/LCL_xxxx”cr”
Response: >add/LCL_xxxx”cr””lf”]
Status Only: <add/LCL_”cr”
Response: >add/LCL_xxxx”cr””lf”]
Where: xxxx = HOLD, NOM, or MAX (power level setting when local carrier loss).
B.2.7.1.8 AUPC Remote Carrier Loss Action
Command: <add/RCL_xxxx”cr”
Response: >add/RCL_xxxx”cr””lf”]
Status Only: <add/RCL_”cr”
Response: >add/RCL_xxxx”cr””lf”]
Where: xxxx = HOLD, NOM, or MAX (power level setting when remote carrier loss).
B.2.7.2 Remote Modem AUPC Commands
Notes:
1. Always wait three seconds between consecutive remote modem command/status
polls.
2. On status-only commands, the first time polled will cause a “???” instead of the
regular data being returned. Retrying a second time (Note 1, in effect), will return
a valid status response.
3. A status poll always returns the data from the last poll.
B.2.7.2.1 Remote AUPC Enable
Command: <add/RPC_xxx”cr”
Response: >add/RPC_xxx”cr””lf”]
Status Only: <add/RPC_”cr”
Response: >add/RPC_xxx”cr””lf”]
Where: xxx = ON or OFF (remote AUPC enable).