Specifications
Remote Control SDM-309B Satellite Modem
B-B–24 MN/U-SDM309B Rev. #
5.16.1 Modulator Stored Faults
Command: <add/MSF_#”cr”
Response: >add/MSF_# hh:mm:ss MM/DD/YY”cr”
MOD_xxx”cr” Module missing or won”t program (OK/FLT)
AGC_xxx”cr” AGC leveled (OK/FLT)
SYN_xxx”cr” Carrier synthesizer (OK/FLT)
BCLK_xxx”cr” Bit clock (OK/FLT)
TCLK_xxx”cr” Transmit clock (OK/FLT)
ICH_xxx”cr” I-channel (OK/FLT)
QCH_xxx”cr””lf”] Q-channel (OK/FLT)
5.16.2 Demodulator Stored Faults
Command: <add/DSF_#”cr”
Response: >add/DSF_# hh:mm:ss MM/DD/YY”cr”
DMD_xxx”cr” Demod module (OK/FLT)
CD_xxx”cr” Carrier detect (OK/FLT)
SYN_xxx”cr” Synthesizer lock (OK/FLT)
ICH_xxx”cr” I-channel (OK/FLT)
QCH_xxx”cr” Q-channel (OK/FLT)
BCLK_xxx”cr” bit clock (OK/FLT)
BERT_xxx”cr””lf”] BER threshold (OK/FLT)
5.16.3 Common Equipment Stored Faults
Command: <add/CSF_#”cr”
Response: >add/CSF_# hh:mm:ss MM/DD/YY”cr”
M&C_xxx”cr Monitor & Control Module (OK/FLT)
INT_xxx”cr” Data Interface Module (OK/FLT)
BAT_xxx”cr” battery (OK/FLT)
PS1_xxx”cr” +5 volt power supply (OK/FLT)
PS2_xxx”cr” +12 volt power supply (OK/FLT)
PS3_xxx”cr””lf”] -12 volt power supply (OK/FLT)
5.16.4 Interface Transmit Side Status
Command: <add/ITSF_#”cr”
Response: >add/ITSF_# hh:mm:ss MM/DD/YY”cr”
CLK_xxx”cr” Selected Transmit Clock Activity (OK/FLT)
DRP_xxx”cr” Drop (OK/FLT)
TXD_xxx”cr””lf”] Transmit Data (OK/FLT)
5.16.5 Interface Receive Side Status
Command: <add/IRSF_#”cr”
Response: >add/IRSF_# hh:mm:ss MM/DD/YY”cr”
MUX_xxx”cr” MUX Lock (OK/FLT)
CLK_xxx”cr” Selected Insert Clock Activity (OK/FLT)