Specifications

SDM-309B Satellite Modem Remote Control
MN/U-SDM309B Rev. # B-B–19
SYN_xxx”cr” Synthesizer lock (OK/FLT)
ICH_xxx”cr” I-channel (OK/FLT)
QCH_xxx”cr” Q-channel (OK/FLT)
BCLK_xxx”cr” bit clock (OK/FLT)
BERT_xxx”cr” BER threshold (OK/FLT)
RSL_-nn.ndBm”cr” Receive Signal Level (level or No Data)
CSV_snnnnn”cr” Current Sweep Value
SFLT_xx”cr””lf”] Number of stored faults logged (0 to 10)
5.5 Common Equipment Status
The common equipment status command causes a block of data to be returned which
indicates the status of the common equipment.
Command: <add/CES_”cr”
Response: >add/CES_”cr”
M&C_xxx”cr Monitor & Control Module (OK/FLT)
INT_xxx”cr” Data Interface Module (OK/FLT)
BAT_xxx”cr” battery (OK/FLT)
PS1_xxx”cr” +5 volt power supply (OK/FLT)
PS2_xxx”cr” +12 volt power supply (OK/FLT)
PS3_xxx”cr” -12 volt power supply (OK/FLT)
MODE_xxxxxx”cr” Mode (LOCAL or REMOTE)
SW_x.xxx”cr” Software Version
SFLT_xx”cr””lf”] Number of stored faults logged (0 to 10)
5.6 Interface Transmit Side Status
Command: <add/ITXS_”cr”
Response: >add/ITXS_”cr”
CLK_xxx”cr” Selected Transmit Clock Activity (OK/FLT)
DRP_xxx”cr” Drop (OK/FLT)
TXD_xxx”cr” Transmit Data (OK/FLT)
SFLT_xx”cr””lf”] Number of Stored Faults Logged (0 to 10)
5.7 Interface Receive Side Status
Command: <add/IRXS_”cr”
Response: add/IRXS_”cr”
MUX_xxx”cr” MUX Lock (OK/FLT)
CLK_xxx”cr” Selected Insert Clock Activity (OK/FLT)
INS_xxx”cr” Insert (OK/FLT)
BWA_xxx”cr” Receive Backward Alarm (OK/FLT)
BER_xxx”cr” Frame BER (OK/FLT)
RXD_xxx”cr” Receive Data Loss/AIS (OK/FLT)
OVFL_xxx”cr” Buffer Overflow (OK/FLT)
UNFL_xxx”cr” Buffer Underflow (OK/FLT)
IRES_xxxx_n.nE-e”cr” Read Error Status
IBFS_nn%”cr” Interface Buffer Fill Status
SFLT_xx”cr””lf”] Number of Stored Faults Logged (0 to 10)