Specifications

SDM-100A Satellite Modem Operation
Rev. 0 3–23
3.2.1.1.4 Configuration Local AUPC
AUPC Enable This option turns the local modem’s AUPC ON or OFF.
Nominal Power This option programs the nominal power set point for AUPC from -30
to -5 dBm.
Minimum Power This option programs the minimum power set point for AUPC from -
30 to -5 dBm.
Maximum Power This option programs the maximum power set point for AUPC from -
30 to -5 dBm.
Target Noise This option programs the target E
b
/N
0
setpoint. The E
b
/N
0
setpoint
can range from 3.2 to 9.7 dB, in 0.1 dB increments.
Tracking Rate This option programs the maximum tracking rate. The maximum
tracking rate can range from 0.5 to 6.0 dBm per minute.
Local CL Action This option programs the action taken by the local modem if Carrier
Loss is detected. The local CL can be programmed to Maximum,
Nominal, or Hold.
Remote CL Action This option programs the action taken by the remote modem if
Carrier Loss is detected. The remote CL can be programmed to
Maximum, Nominal, or Hold.