Product specifications
CDM-600 Satellite Modem   Revision 7 
Remote Control   MN/CDM600.IOM 
16–30 
Parameter 
Type 
Command 
(Instruction 
Code and 
Qualifier) 
Arguments for 
Command or 
Response to 
Query 
Description of Arguments 
Response 
to 
Command 
Query 
(Instruction 
Code and 
Qualifier) 
Response to Query 
Retrieve next 
5 unread 
Stored 
Events 
N/A  80 bytes  Query only. 
Unit returns the oldest 5 Stored Events which have not 
yet been read over the remote control. 
Reply format: [CR]sub-body[CR]sub-body[CR]sub-
body[CR]sub-body[CR]sub-body, where Sub-
body=ABCddmmyyhhmmss, 
A is the fault/clear indicator: 
 F=Fault 
 C=Clear 
 I=Info 
B is the fault type where: 
 1=Unit 
 2=Rx Traffic 
 3=Tx Traffic 
 4=Power on/off, or log cleared 
 5=Open Network 
C is Fault Code number, as in FLT? 
 or Info Code, which is: 
 0=Power Off 
 1=Power On 
 2=Log Cleared 
 3=Global Config Change 
 4=Redundancy Config Change 
ddmmyyhhmmss = date/time stamp. 
If there are less than 5 events to be retrieved, the 
remaining positions are padded with zeros. 
If there are no new events, the response is RNE*. 
N/A RNE? RNE=[CR]ABCddmm
yyhhmmss[CR]ABC
ddmmyyhhmmss[CR
]ABCddmmyyhhmm
ss[CR]ABCddmmyy
hhmmss[CR]ABCdd
mmyyhhmmss 
(see description for 
details of 
arguments) 
Clear All 
Stored 
Events 
CAE= None  Command only. 
Forces the software to clear the software events log. 
Example: CAE= 
Note: This command takes no arguments 
CAE= 
CAE? 
CAE* 
CAE# 
N/A N/A 