Product specifications
CDM-600 Satellite Modem   Revision 7 
Remote Control   MN/CDM600.IOM 
16–28 
Parameter 
Type 
Command 
(Instruction 
Code and 
Qualifier) 
Arguments for 
Command or 
Response to 
Query 
Description of Arguments 
Response 
to 
Command 
Query 
(Instruction 
Code and 
Qualifier) 
Response to Query 
Statistics 
Sample 
Interval 
SSI=  1 byte, 
numerical 
Command or Query. 
Used to set the sample interval for the Statistics Logging 
Function 
SSI=x, where x= 0 to 9 in 10 minute steps. 
Note: Setting this parameter to 0 disables the statistics 
logging function. 
Example: SSI=3 means 30 minutes 
SSI= 
SSI? 
SSI* 
SSI# 
SSI? SSI=x 
(see description for 
details of argument) 
Number of 
Unread 
stored 
Statistics 
N/A  3 bytes  Query only. 
Unit returns the number of stored Statistics, which 
remain Unread, in the form xxx (0-199). 
Note: This means unread over the remote control. 
Example: NUS=187 
N/A NUS? NUS=xxx 
(see description of 
arguments) 
Retrieve next 
5 unread 
Stored 
Statistics 
N/A  135 bytes  Query only. 
Unit returns the oldest 5 Stored Statistics, which have 
not yet been read over the remote control. 
Reply format: 
[CR]sub-body[CR]sub-body[CR]sub-body[CR]sub-
body[CR]sub-body, 
where Sub-body=AA.ABB.BC.CD.Dddmmyyhhmmss, 
 AA.A=Minimum Eb/No during sample period. 
 BB.B=Average Eb/No during sample period. 
 C.C=Max. Tx Power Level Increase during sample 
period. 
 D.D=Average Tx Power Level Increase during sample 
period. 
 ddmmyyhhmmss = date/time stamp. 
If there are no new events, the unit replies with RNS*. 
If there are less than 5 statistics to be retrieved, the 
remaining positions are padded with zeros. 
N/A RNS? RNS=[CR]AA.ABB.B
C.CD.Dddmmyyhhm
mss[CR]AA.ABB.BC.
CD.Dddmmyyhhmm
ss[CR]AA.ABB.BC.C
D.Dddmmyyhhmmss
[CR]AA.ABB.BC.CD.
Dddmmyyhhmmss[C
R]AA.ABB.BC.CD.Dd
dmmyyhhmmss 
(see description for 
details of 
arguments) 