Product specifications
CDM-600 Satellite Modem   Revision 7 
Remote Control   MN/CDM600.IOM 
16–19 
Parameter 
Type 
Command 
(Instruction 
Code and 
Qualifier) 
Arguments for 
Command or 
Response to 
Query 
Description of Arguments 
Response 
to 
Command 
Query 
(Instruction 
Code and 
Qualifier) 
Response to Query 
Invert Rx 
Data 
IRD=  1 byte, 0 or 1  Command or Query. 
Invert Receive Data 
 0=Normal 
 1=Inverted 
Example: IRD = 1 (selects Inverted RX Data) 
IRD= 
IRD? 
IRD* 
IRD# 
IRD?  IRD=x 
(see description of 
arguments) 
Rx Demod 
Acquisition 
Sweep Width 
RSW=  2 bytes  Command or Query. 
Rx ± acquisition sweep range of demodulator, in kHz, 
ranging from ± 1 to ± 32 kHz 
Example: RSW=09 (selects ± 9 kHz) 
RSW= 
RSW? 
RSW* 
RSW# 
RSW?  RSW=xx 
(see description of 
arguments) 
Rx Clock 
Source 
RCK= 1 byte, value 
of 0 thru 3 
Command or Query. 
Rx Clock Source, where: 
 0=Rx Satellite 
 1=Tx-Terrestrial 
 2=External Clock Source 
 3=INSERT (command valid only when Rx framing is 
  Insert or D&I++ and interface is G.703 or set for 
 D&I loop. 
Example: RCK=1 (selects Tx-Terrestrial) 
RCK= 
RCK? 
RCK* 
RCK# 
RCK? RCK=x 
(see description of 
arguments) 
Eb/No Alarm 
Point 
EBA=  4 bytes  Command or Query. 
Eb/No alarm point in dB, with a range between 0.1 and 
16 dB. 
Resolution=0.1 dB 
Example: EBA=12.3 
EBA= 
EBA? 
EBA* 
EBA# 
EBA? EBA=xx.x 
(see description of 
arguments) 
Rx Buffer 
Size 
RBS=  5 bytes  Command or Query. 
Rx Buffer Size, 16 to 32768 bytes, in 2-byte steps, unless 
other limitations apply. (See 6.3.1.5) 
Example: RBS=08192 (selects 8192 bytes) 
RBS= 
RBS? 
RBS* 
RBS# 
RBS? RBS=xxxxx 
(see description of 