Unit installation

Installation RSU-503 Redundancy Switch Unit
20 Rev. 8
2.4.6.2 LNA Plate to Waveguide Switch
The following table outlines the pinouts of the LNA plate to Waveguide Switch cable.
This cable is internal on the redundant LNA plate.
Note:
This pinout table may be helpful if an EFData Waveguide Switch is used.
Name Pin # Function
Command, Position 1 A +28V pulse for 500 milliseconds
Command Common B Ground
Command, Position 2 C +28V pulse for 500 milliseconds
Indicator, Position 1 D Connects to Common when in position 1
Indicator Common E Ground
Indicator, Position 2 F Connects to Common when in position 2
2.4.7 TX/RF Output (J11)
The TX/RF Output connector is a 50
type N connector used to monitor the transmit
output signal from the offline RFT. This connector is used to test the offline unit.
2.4.8 TX/IF Input (J12)
The TX/IF Input connector is a 50
TNC connector used to input the IF test signal to the
offline RFT. This connector is used to test the offline unit.
2.4.9 RX/IF Output (J13)
The RX/IF Output connector is a 50
TNC connector used to monitor the IF output
signal from the offline RFT. This connector is used to test the offline unit.
2.4.10 TX/IF Input (J14)
The TX/IF Input connector is a 50
TNC connector used to receive the IF uplink signal
from the modem. The switch routes the signal to the online RFT for transmission.
2.4.11 RX/IF Output (J15)
The RX/IF Output connector is a 50
TNC connector used to provide the IF downlink
signal to the modem (after the signal is picked up by the antenna and routed through the
online LNA and RFT).