Product specifications
CDM-Qx Satellite Modem Revision 4
Remote Control MN/CDMQx.IOM
C-31
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response
to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
Unit ID N/A
7 bytes
Query only
Unit returns information concerning the base unit
identification and the option field in the form: abcdefg
a=Redundancy option: 0=None, 1=1:1 mode, 2=1:2
mode, 3=1:3 mode.
Note: if a=3, capable of supporting also1:2 and 1:1.
If a=2, capable of supporting 1:1 as well.
b=CnC First Instance rate option:
0=None,
1=128 Kbps to 512Kbps,
2=128Kbps to 1Mbps,
3=128Kbps to 2.5Mbps,
4=128Kbps to 5Mbps,
5=128Kbps to 10Mbps,
6=128Kbps to 20Mbps.
c=CnC Second Instance rate option:
0=None,
1=128 Kbps to 512Kbps,
2=128Kbps to 1Mbps,
3=128Kbps to 2.5Mbps,
4=128Kbps to 5Mbps,
5=128Kbps to 10Mbps,
6=128Kbps to 20Mbps.
d=Unit Type
0=70/140MHz unit
1=L-Band unit with one 24V power supply
2=L-Band unit with one 48V power supply
3=L-Band unit with two 24V power supplies
4=L-Band unit with two 48V power supplies
e=D&I++ option
0=None
1=One modem only
2=Two modems
f=spare
g=spare
N/A UID? UID=abcdefg
(see description of