Product specifications
CDM-Qx Satellite Modem Revision 5
Front Panel Operation MN/CDMQx.IOM
5–53
5.6.2 MONITOR
Select Alarms, Rx-Params, Event-Log, Stats, AUPC, CnC or ODU using the
◄ ► arrow keys, then press ENT. The ODU menu will only appear for 70/140MHz
units.
If the user selects Alarms, the following sub-menu is displayed:
5.6.2.1 (MonitorAlarms) ALARMS
The modem uses a system of Fault Prioritization. In each category of fault,
only the highest priority fault is displayed. For instance, if the demodulator is
unlocked, it is irrelevant if there are other receive faults present. If the
demodulator then locks, but there is a fault of a lower priority present, this will
then be displayed. This also holds true for the faults reported via the remote
control. This system cuts down drastically on unwanted and irrelevant fault
reporting. A comprehensive list of faults is shown at the end of this section.
Select Transmit, Receive, or Unit using the WXarrow keys, then press ENT. Depending
on the choice , one of the following menus will be shown:
(MonitorAlarmsUnit) – UNIT ALARMS
The screen will indicate if there are any Unit Faults. If not, it will display ‘None’.
Pressing ENT takes the user back to the previous menu.
MONITOR: Alarms Rx
-
P
arams
Event-Log Stats AUPC CnC ODU
Unit Fault:
-
1
2 Volt PSU
is under voltage (ENT)
Live Alarms: Transmit
Receive Unit ODU (◄ ►,ENT)
IMPORTANT